IES-0820 User Manual Page 4
Product Highlights
Basic Features
• Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock, and
vibration for traffic control equipment.
• Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial
environment.
• UL1604 Class I, Division 2 Classified for use in hazardous locations (applicable to
versions with terminal block power option).
• Supports 802.3/802.3u/802.3X.
• Auto-negotiation: 10/100Mbps, full/half-duplex. Auto MDI/MDIX.
• Supports 2048 MAC addresses.
• Provides 768K bits memory buffer.
• Alarms for power and port link failure by relay output 1.5A @ 24VDC.
• Operating voltage and Max. current consumption: 0.76A @ 12VDC, 0.38A @ 24VDC,
0.19A @ 48VDC. Power consumption: 9.12W Max.
• Power Supply: Redundant DC Terminal Block power inputs or 12VDC DC JACK with
100-240VAC external power supply.
• Field Wiring Terminal: Use Copper Conductors Only, 60/75℃, 12-24 AWG torque value 7
lb-in.
• -40℃ to 75℃ (-40℉ to 167℉) operating temperature range. Tested for functional
operation @ -40℃ to 85℃ (-40℉ to 185℉). UL1604 Industrial Control Equipment
certified Maximum Surrounding Air Temperature @ 74℃ (165℉).
• Supports DIN-Rail or Panel Mounting installation.