Symptom
.The EVAP cools down and warms
again.
.The condenser warms in proportion
as the EVAP cools.
.The process repeats again.
Moisture in the refrigerant
causes the malfunction.
defective.
Refrigerant leaks.
Suggestions
4.Trouble check for the cooling cycle
.The condenser is cold.
.The EVAP is not cold.
.The tem perature of the compressor
is high.
.No difference in tem peratures
between suction pipe and discharge
pipe.
.The temperature of the compressor
is maintained at room temperature.
.The EVAP does not cool down.
.Frost on the suction pipe.
.The condenser is overheated.
.The refrigeration in the EVAP is
not effecient.
.The condenser is cold.
.The compressor surface temperature
is high.
.The refrigeration is not easily get
cooled.
Replace the refrigerant.
Located the disturbed section
and make repairs.
Replace the compressor.
Replace the refrigerant.
After welding the leaked
spot, replace the refrigerant.