DATA ACCESS PANEL FBs-DAP
1.2 Important points before operation
1、 FBs-DAP possesses a function to return to the operation mode (general data setter and self-defined 8/16
special keys) before power failure and each DAP can be place in a different mode when connecting many sets.
2、 When operating FBs-DAP,D2944~D3071 register of PLC will be used as the system configuration area (most
data set by FUN functions are stored here) , the user shall avoid this area.
3、 Any communication port, once converted to a RS485 interface, can be connected to a maximum of 16
FBs-DAP-B(R) sets.
4、 When PLC is connected with FBs-DAP-B(R),the station number of PLC is limited to a range of 1~32.
5、 The communication parameter of connections between PLC and FBs-DAP-B(R) are:
port0、1、2:9600 / 19200 / 38400、Even、7 Data bits、1 Stop bit
(DAP automatic detection baud rate 9600 / 19200 / 38400)
ex:R4158=5521H, i.e. port2 being 9600;R4158=5523H, i.e. port2 being 38400.
6、 When many sets of DAP are connected, if any two or more have the same station number, then DAP will
request for number change, which can be done by only entering〝
new DAP NO.
” keys。
7、 The transmission line of the RS-485 interface must use a twisted pair with a shielded cover on the outer layer.
Please refer to chapter 11 in the Operation Manual II for other important points.
8、 The scanning time of PLC will affect the update time of DAP.
9、 When Proladder(or FP-08) and DAP are connected to the same set of PLC, to change the program through
Proladder is not allowed; if so, the timer information displayed by DAP won’t be correct (In this case, the DAP
shall be reset).
10、FP-08 is capable of entry of common with up to 16 characters for contacts and registers editing.