114113-B Rev. 00
Determine the clearance and creepage distance between adjacent points as
follows:
The clearance distance (X) is the shortest distance between two points
through the air.
The creepage distance (Y) is the shortest distance between two points
measured across a surface.
If you have any questions, consult a competent telecommunications safety
engineer. Failure to install the ISDN BRI according to these instructions will
invalidate the General Approval.
Table D-13. ISDN BRI Clearances and Creepage Distances
Clearance (X) Creepage (Y)
Voltage Used or Generated by Other Parts
of the Host or Expansion Card
2.0 mm 2.4 (3.8) mm Up to 50 V rms or VDC
2.6 mm 3.0 (4.8) mm Up to 125 V rms or VDC
4.0 mm 5.0 (8.0) mm Up to 250 V rms or VDC
4.0 mm 6.4 (10.0) mm Up to 300 V rms or VDC