Dil ID: 8
Dil Adı: italy
Dil Kodu: it6tayfun Prodotti del Marchio Acura Embedded
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



Appendix D: Power Consumption
Appendix D: Power Consumption
Power Consumption Management
Purpose
The purpose of the power consumption test is to verify the power dissipation
of the system and the load of the power supply.
Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver:2.0
Device Under Test
DUT: sys#1/
Test Procedure
1. Power up DUT and then boot Windows 7.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.
AcuPanel 17
Full-Loading Mode
Total
Standby Mode
Total
+12V
4.2A
50.4W
0.74A
8.88W
+24V
2.0A
48W
0.41A
9.84W
+30V
1.63A
48.9W
0.34A
10.2W
83