Installation (for qualified installers only) 17
Travis Industries 4040708 100-01160
Vent Requirements
! The vent must maintain the required clearance to combustible materials to prevent a fire (see
Clearances below). Do not fill air spaces with insulation.
! The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it's own separate vent system.
Altitude Considerations
This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing we have
found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.
! Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.
Clearances
Minimum 1 clearance to all combustibles (measured from the outside of the pipe) except for the following:
2" Clearance
With any vertical
vent directly off the
fireplace, the
clearance is 1".
1" Clearance
When using 6-5/8" vent, a
horizontal termination, and
an elbow directly off the
top of the fireplace, a 2"
clearance is required
above the horizontal
sections (1" to the side
and below).
Max. 3'
Horizontal
Run
Use of 8 Diameter Pipe
Most venting configurations use 6-5/8 diameter vent. To achieve longer horizontal runs (over 12)
with a horizontal termination, 8 dia. Simpson Duravent type GS Direct Vent may be used. See the
section Horizontal Terminations using 8 Diameter Vent for details. Part Numbers are listed below.
Straight Lengths
1208B 6" Pipe Length, Black
1207B 9" Pipe Length, Black
1206B 12" Pipe Length, Black
1204B 24" Pipe Length, Black
1203B 36" Pipe Length, Black
1202B 48" Pipe Length, Black
1211B 11 to 14-5/8" Adjustable Pipe,
Black
Terminations
1284 Horizontal Square Termination
1285 Hor. High Wind Termination
1250 Vinyl Siding Stand-off
Elbows
1245B 45° Elbow, Black
1290B 90° Elbow, Black
Penetration, Support
1242 Wall Firestop
1241 Cathedral Ceiling Support Box
1263 Ceiling Fire-stop
1288 Wall Strap
Adapter (6-5/8 to 8 dia.)
925T DV GS 6-5/8 to 8 Increaser
Part Numbers for 6-5/8 Diameter Vent
Use Model GS Direct Vent manufactured by Simpson Dura-Vent only
. Follow the installation
instructions included with the vent. For the nearest Simpson Dura-Vent supplier, call (800) 835-4429.
Vent part numbers and descriptions are listed below.
Straight Lengths
908B 6" Pipe Length, Black (interior)
907B 9" Pipe Length, Black (interior)
906 12" Pipe Length, Galvanized
906B 12" Pipe Length, Black (interior)
904 24" Pipe Length, Galvanized
904B 24" Pipe Length, Black (interior)
903 36" Pipe Length, Galvanized
903B 36" Pipe Length, Black (interior)
902 48" Pipe Length, Galvanized
902B 48" Pipe Length, Black (interior)
911B 11" to 14 5/8" Adjustable, Black (interior)
Vent Terminations
981 Snorkel Termination (36" rise)
(for basement or raised
termination installations)
982 Snorkel Termination (14" rise)
(for basement or raised
termination installations)
984 Horizontal Square Termination
950 Vinyl Siding Stand-off
991 High Wind Vertical
Termination
Elbows
990 90 Elbow
990B 90 Elbow, Black (interior)
Penetration, Support
942 Wall Thimble
941 Cathedral Ceiling Support Box
943 Flashing, 0/12 to 6/12 Roof Pitch
943S Flashing, 7/12 to 12/12 Roof Pitch
953 Storm Collar
963 Ceiling Fire-stop
988 Wall Strap