701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
VENTLESS
FRONT LOADING DISHWASHER
Page 8 of 8 F-40273 – Ventless Front Loading Dishwasher
COLD WATER: Cold water supplied to condenser coil
is heated during the condensing period at the end of
each cycle. This pre-heated water is supplied to the
booster for subsequent heating.
DRAIN AND OVERFLOW: Large bell type automatic
overow and drain valve controlled from inside of
machine. Drain automatically closed by lowering
chamber. Drain seal is large diameter, high tempera-
ture “O” ring. Cover for overow is integral part of the
standpipe.
STRAINER SYSTEM: Equipped with large, exclusive
self-ushing, easily removable perforated stainless
steel, one-piece strainer and large capacity scrap
basket. Submerged scrap basket minimizes frequent
removal and cleaning.
HEATING EQUIPMENT: Standard tank heat is 5 KW
electric immersion heating element. Water tempera-
ture regulation is controlled by thermistor sensor in
combination with microcomputer controls. The tank
heat and positive low water protection microcomputer
circuits are automatically activated when the main
power switch is turned “on”. If tank is accidentally
drained, low water protection device automatically
turns heat off. These features are standard with the
Hobart Microcomputer Control System.
ENERGY RECOVERY: Heat energy is recovered from
the condensation of vapors in the chamber at the end
of each cycle. This pre-heats the water for the next
rinse cycle from 55°F up to 140°F.
ELECTRIC BOOSTER HEATER: 8.5 KW electric
booster with Sense-A-Temp
TM
technology adequately
sized to raise 110°F inlet water to 180°F.
ACCESSORIES: 19
3
⁄4" x 19
3
⁄4" peg and combination
dish racks. Splash shield for corner installations. End
of cycle audible alarm (eld activated). Delime notica-
tion (eld activated). Desirable functional accessories
can be furnished at added cost. See listed options
and accessories on this specication sheet. Write to
the factory for special requirements not listed above.
F-40273 (REV. 05/11) LITHO IN U.S.A. (H-01)