Location requirements
All Monogram refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for air
circulation.
• Do not install these products where the temperatures will
go below 55°F (13°C) or above 90°F (32°C).
• Do not install where they will be subject to direct
sunlight, heat or moisture.
• These products are not designed to be stacked one over
the other.
Electrical
A 120V, 60HZ., 15- or 20-amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall of the installation
opening. See cutout illustration.
The serial plate is located below the bottom drawer liner on
the left side.
Note: GFCI (ground fault circuit interrupter) is not recommended.
Side-by-side installation
For the ultimate in convenience, install two double-drawer
refrigerators together.
• Products must operate from separate properly
grounded receptacles.
3/4" custom panels for
double-drawer refrigerator
Field-installed overlay drawer panels are required for
model ZIDI240WII.
• The overlay panel must be secured to a 1/4"-thick backer
panel that slides into the drawer trim. A 0.10"-thick spacer
panel must be placed between the overlay and backer panel.
• Custom handles of your choice must be installed onto the
assembled overlay panels.
Advance planning for double-drawer refrigerator
Overlay
Panel
1/4"
Backer
Panel
Door
3/4" custom panels for
fresh food and bar refrigerator
3/4" custom panels for
double drawer refrigerator
.10 Inch
Spacer
B
A
1/4" Gap
12-1/2 lbs. max.
B
12-1/2 lbs. max.
3/8
3/4
Right
side
view
of
overlay
custom
panel
Route
for hinge
clearance
Front
7/8
3/8
Top
view
of
overlay
custom
panel
Route
for hinge
clearance
Front
A
B
Spacer Panel
Backer Panel
Overlay Panel
Overlay
Panel
1/4"
Backer
Panel
Door
.10 Inch
Spacer
Spacer Panel
Backer Panel
Overlay Panel
Overlay
Panel
1/4"
Backer
Panel
Door
3/4" custom panels for
fresh food and bar refrigerator
3/4" custom panels for
double drawer refrigerator
.10 Inch
Spacer
B
A
1/4" Gap
12-1/2 lbs. max.
B
12-1/2 lbs. max.
3/8
3/4
Right
side
view
of
overlay
custom
panel
Route
for hinge
clearance
Front
7/8
3/8
Top
view
of
overlay
custom
panel
Route
for hinge
clearance
Front
A
B
Spacer Panel
Backer Panel
Overlay Panel
Overlay
Panel
1/4"
Backer
Panel
Door
.10 Inch
Spacer
Spacer Panel
Backer Panel
Overlay Panel
Maximum assembled panel weight is
25 pounds (12-1/2 pounds for each panel).
3/4" overlay panel dimensions (in inches)
A (width) B (height)
1/4" backer 23-3/16" 14-11/16"
0.10" spacer 22-1/2" 14-3/16"
3/4" overlay 23-5/8" 15-1/16"
Assemble overlay panels with glue and screws.
• Center spacer panel on the backer panel, left to right, and top
to bottom. Secure the panels with glue.
• Center the spacer/backer panel on the overlay panel. Secure
with glue and screws. Countersink all screws.
Note: Maintain 1/4" gap between the
drawer panels.