Dil ID: 7
Dil Adı: french
Dil Kodu: fr2tayfun Produits de la Marque Siemens
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



ST700 GENERAL HANDBOOK
667/HB/27880/000 Page 89 Issue 8
Checks all of the triacs in turn by applying a very short pulse to each
phase’s colour:
A/Red:Extra Sigs On
R-00000001+00000001
A-00000001+00000001
G-00000001+00000001
A fault will be logged if extra signals are detected as on when one particular aspect is
pulsed. This would normally imply a short-circuit in the street cabling or a open
neutral connection.
No Voltages On...
R-00000000+00000000
A-0000000A+0000000A
G-00000000+00000000
A fault will also be logged if no voltages were detected, e.g. when one of the fuses
has blown.
In the example above, 0000000A represents phases B and D (see Figure 22), so
Amber (from RAG down the left-hand side) shows that the pedestrian Wait indicators
have no voltages present. Check the fuses F6 and F8 and the 48V output from the
dimming transformer for example.
At the end of the test, the self-test switches off the lamp supply and displays a
multicoloured scrolling pattern on the LEDs to show that all the tests have passed
successfully.
It also illuminates a series of LEDs to identify which cards on the extended system
bus have been detected. A full list is displayed on the handset.
After a few seconds, self-test will repeat the second part of the self-test allowing the
controller to be soak tested.