217
Configuring EAA
Overview
Embedded Automation Architecture (EAA) is a monitoring framework that enables you to self-define
monitored events and actions to take in response to an event. It allows you to create monitor policies by
using the CLI or Tcl scripts.
EAA framework
EAA framework includes a set of event sources, a set of event monitors, a real-time event manager (RTM),
and a set of user-defined monitor policies, as shown in Figure 63.
Figure 63 EAA framework
Event sources
Event sources are software or hardware modules that produce events (see Figure 63). For example, the
CLI module creates an event when you enter a command, and the Syslog module (the information center)
produces an event when it receives a log message.
Event monitors
One event monitor is created for one monitor policy to monitor the system for the event specified in the
policy. An event monitor notifies the RTM to run the specific monitor policy when the monitored event
occurs.
RTM
EM
Hotplug
CLI Syslog SNMP
ProcessInterfcae
SNMP-
notification
EAA monitoring policies
CLI-based policy TCL policy
Event sources