Issue Date: 2010-03-02 Page 4 of 13 Report Reference # E336418-A29-UL
2010-10-22
The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 40 degree C and for model For GT-41069P9012-T3,
add Tma 60 degree C under output 12Vdc, 4A.
The means of connection to the mains supply is: Pluggable A, Detachable power cord,
The product is intended for use on the following power systems: TN
The equipment disconnect device is considered to be: Appliance inlet ,
The following circuit locations (with circuit/schematic designation) were investigated as a limited
power source (LPS): Output for Models GT-41069P9012-T3YZ and GT-41069PWW24-X.X-T3YZ.
The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual
The equipment employs Functional Earthing per 2.6.2. As anticipated by the NOTE for 1.2.4, it does
not conform to one of the common Classes (I, II, or III). The following insulation is provided between
the primary and accessible dead metal parts and circuits: Reinforced , Double
Additional Information
Issue 1, Amendment No. 2:
Add LPS test for Models GT-41069P9012-T3YZ and GT-41069PWW24-X.X-T3YZ.
Markings and instructions
Clause Title Marking or Instruction Details
Power rating - Ratings Ratings (voltage, frequency/dc, current)
Power rating - Company
identification
Listee's or Recognized company's name, Trade Name, Trademark or File Number
Power rating - Model Model Number
Fuses - Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder.
Special Instructions to UL Representative
Inspect the transformer(s) listed in table "Electric Strength Test Special Constructions" per AA1.1– (C):
When the tests are conducted at other location, inspect test record and specification sheet provided by the
component manufacturer. Verify the specification sheet indicates 100% routine test specified in the table be
conducted at the component manufacturer.