Issue Date: 2008-10-28 Page 8 of 10 Report Reference # E170507-A26-UL-1
IEC 60950-1
SubClause Difference + Test Result - Remark Verdict
Underwriters Laboratories Inc.
in equipment complies with ANSI/NFPA 30(Table
NAE.6).
4.3.12 Equipment using replenishable liquids marked to
indicate type of liquid to be used.
N/A
4.3.13.2 Equipment that produces x-radiation and does not
comply with 4.3.12 under all conditions of servicing
marked to indicate the presence of radiation where
readily visible.
N/A
4.3.13.5 Requirements contained in the applicable national
codes and regulations apply to lasers (21 CFR
1040 and REDR C1370).
N/A
4.7
utomated information storage equipment intended
to contain more than 0.76 m³ of combustible media
requires provision for automatic sprinklers or a
gaseous agent extinguishing system.
N/A
4.7.3.1 Equipment for use in environmental air space other
than ducts or plenums provided with metal
enclosure or with non-metallic enclosure having
adequate fire-resistance and low smoke producing
characteristics. Low smoke-producing
characteristics evaluated according to UL 2043.
Equipment for installation in space used for
environmental air as described in Sec. 300-22(c) of
the NEC provided with instructions indicating
suitability for installation in such locations.
N/A
4.7.3.1 Flame spread rating for external surface of
combustible material with exposed area greater
than 0.93 m² or a single dimension greater than 1.8
m; 50 or less for computer room applications or
200 or less for other applications.
N/A
4.7.3.4 Wire marked "VW-1" or "FT-1" considered
equivalent.
Pass
5.1.8.2 Special earthing provisions and instructions for
equipment with high touch current due to
telecommunication network connections.
N/A
5.1.8.3 Touch current due to ringing voltage for equipment
containing telecommunication network leads.
N/A
5.3.6 Overloading of SELV connectors and printed wiring
board receptacles accessible to the operator.
N/A
5.3.6 Tests interrupted by opening of a component
repeated two additional times.
N/A
5.3.8.1 Test interrupted by opening of wire or trace subject
to certain conditions.
N/A