Owner’s Guide & Installation Instructions
11 / English
Installation Instructions
Allowable Clearances for Undercounter Installation
Thedimensionsarefortherecommendedspacing.Counterdepthshouldbe23.5-24.5”(60-62cm).
Custom undercounter installation – Washer only
Minimumcounterwidthshouldbe50”(127cm)forapairofBlombergwasher&dryer.
Customundercounterinstallation–Washer&Dryer
50Ó
(127 cm)
Allowable Clearances for Closet Installation
When installed in closet (washer only/washer dryer stacked) :
Sides, Rear, Front 1/2 in. (1.27 cm), Top= 1 in. (2.54 cm)
Closet door ventilation requirement: A louver having minimum 23 in2 (148 cm2) air opening located at
3 in (7.62 cm) from the bottom of closet door.
Stacked Installation
You can stack your Blomberg washer and dryer (model no: DV 16540 NBL00) by using a special
stackingkit(PartNo.2967100100).Ifnecessary,consultyourdealerortechnicalserviceforsupplying
the stack kit. In stacked closet installation, following configuration is necessary:
A louver having minimum 23 in2 (148 cm2) air opening located at 3 in (7.62 cm) height from the
bottomofclosetdoor(forwasher)&Alouverofminimum46in2(297cm2)airopeninglocatedat3in
(7.62 cm) distance from the top of closet door (for dryer).
Removing packaging reinforcement
Tilt the washer to remove the packaging reinforcement. Remove the packaging reinforcement by
pulling the ribbon.