Image Quality Adjustment
6
6-28 bizhub PRESS C1100/C1085 (IC-602)
6.2
For details about the setting procedure, refer to the [HTML User's Guide].
NOTICE
If the setting value is changed in the [Custom Screen], hue may fluctuate significantly. To manage the hue
fluctuation, specify the standard image quality following the procedure if you changed the setting value.
Tips
- "Exact Color" and "G7 Calibration", which are high-level calibration functions, are set so that either one
of them is available. If you want to change the function, contact your service representative.
6.2.6 Particular adjustment
If a particular adjustment is required, for example, before printing out an image with a higher level of quality
or when the expected chromogenic effect has not been obtained as expected, adjust the following items:
d Reference
For details about the adjustment procedure, refer to the [HTML User's Guide].
NOTICE
Precaution on using [Color Density Control]
To use [Each Paper Type Color Adj.] in [Color Density Control], carry out [Each Paper Type Color Adj.] before
starting this procedure, then configure a tray setting.
For details, refer to the [HTML User's Guide].
Adjustment
order
Menu item Description Reference
1 Gamma Auto-
matic Adj.
Adjusts the curve of the output density against
the input density.
This affects the brightness and contrast.
On the [MACHINE] screen, select [Adjustment] -
[Execute Adjust Operation] - [Gamma Automatic
Adj.] to execute processing.
[HTML User's
Guide]
2Maximum Den-
sity Adjustment
Changes the maximum density adjustment value
when the measurement density that was ob-
tained after calibration does not match the refer-
ence adjustment value.
[Administrator Setting] - [System Setting] - [Ex-
pert Adjustment] - [Process Adjustment] - [Maxi-
mum Density Adjustment]
[HTML User's
Guide]
3-a Color Density
Control (recom-
mended)
Executes automatic calibration.
On the [MACHINE] screen, select [Adjustment] -
[Color Density Control] - [Basic Setting] or [Color
Density Manual Control] to carry out the adjust-
ment.
p. 6-16
3-b Printer control-
ler calibration
(when [Color
Density Control]
is not used)
Executes manual calibration when [Color Density
Control] is not used.
Use Color Centro.
p. 6-21