Dil ID: 10
Dil Adı: spain
Dil Kodu: es3tayfun Productos de la Marca Kenmore
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



PERFORMANCE DATA SHEET
Base Grille Water Filtration System
Model T1KB1/T1RFKB1 Capacity 100 Gallons (379 Liters)
System tested and certified by NSF internationai against NSF/ANSi Standard 42 for the reduction of
Chiorine Taste and Odor, Particuiate Ciass i*; and against NSF/ANSi Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene, 0-Dichiorobenzene, Cysts, Turbidity, Asbestos, Lindane,
Tetrachioroethyiene, Endrin, Aiachior, Chiorobenzene, Ethyibenzene, TTFIM, MTBE and VOC.
This system has been tested according to NSF/ANSi Standards 42 and 53 for the reduction of the substances iisted beiow. The
concentration of the indicated substances in water entering the system was reduced to a concentration iess than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum % Average %
Aesthetic Effects Requirements Influent Concentration Effluent Effluent Reduction Reduction
Chlorine Taste/Odor 50% reduction 2.0 mg/L 2.0 mg/L ± 10% 0.08 mg/L 2.0 mg/L 95.93 97.36
Particulate Class 1* 85% reduction 3533333#/mL At least 10,000 partioles/mL 22000 #/mL" 11567 #/mL 99.38 99.67
Contaminant NSF Reduction Average Influent Challenge Maximum Average Minimum % Average %
Reduction Requirements Influent Concentration Effluent Effluent Reduction Reduction
Lead: @ pFI 6.5 0.010 mg/L 150 ug/L 0.15 mg/L± 10% 1.0 ug/L
1 ug/L
99.33 99.33
Lead: @ pH 8.5 0.010 mg/L 157 ug/L 0.15 mg/L± 10% 2.0 ug/L 1.08 ug/L 98.72 99.31
Mercury: @ pH 6.5 0.002 mg/L 0.0058 mg/L 0.006 mg/L ± 10% 0.0002 mg/L 0.0002 mg/L 96.53 96.53
Mercury: @ pH 8.5 0.002 mg/L 0.0057 mg/L 0.006 mg/L± 10% 0.0002 mg/L 0.0002 mg/L 96.5 96.5
Benzene 0.005 mg/L 15 ug/L 0.015 mg/L± 10% 0.5 ug/L 0.5 ug/L 96.67 96.67
O-Dichlorobenzene 0.6 mg/L 1750 ug/L 1.8 ± 10% 1.0 ug/L 1.0 ug/L 99.94 99.94
Toxaphene 0.003 mg/L 15 ug/L 0.015 ± 10% 1.0 ug/L 1.0 ug/L 93.33 93.33
Atrazine 0.003 mg/L 10 ug/L 0.009 mg/L± 10% 2 ug/L 2 ug/L 80.8 80.8
Asbestos 99% 101 MEL 10* to 10®fibers/L** 0.17 MEL 0.17 MEL 99.83 99.83
Live Cysts* >99.95% 120,000/L 50,000/L min. 8/L* 1/L» 99.99 >99.99
Turbidity 0.5 NTU 11.4 NTU 11± 1 NTU 0.41 NTU 0.24 NTU 96.4 97.89
Aiachior 0.002 mg/L 41.3 ug/L 0.04 ± 10% 0.2 ug/L 0.2 ug/L 99.52 99.52
Endrin 0.002 mg/L 5.9 ug/L 0.006 ±10% 0.5 ug/L 0.3 ug/L 91.5 95.47
Ethylbenzene 0.7 mg/L 1867 ug/L 2.1 ± 10% 0.70 ug/L 0.0588 ug/L 99.96 100
Lindane 0.002 mg/L 1.9 ug/L 0.002 ± 10% 0.02 ug/L 0.02 ug/L 98.93 98.93
Chlorobenzene 0.6 mg/L 2.0 ug/L 2.0 ± 10% 0.0005 ug/L 0.0005 ug/L 99.98 99.98
Tetrachioroethyiene 0.005 mg/L 14.2 ug/L 0.015 ± 10% 0.5 ug/L 0.5 ug/L 96.47 96.47
TTHM 0.080 mg/L 465 ug/L 0.45 ± 20% 1.0 ug/L 0.5 ug/L 99.78 99.88
MTBE 0.005 mg/L 14 ug/L 0.015 ± 20% 0.70 ug/L 0.52 ug/L 94.94 96.27
VOC 0.015 mg/L 0.3520 mg/L 0.300 ± 10% 0.0060 mg/L 0.0008 mg/L 98.4 99.78
Test Parameters: pFI = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model T1KB1: The filter monitor system measures the amount of
water that passes through the filter and alerts you to replace the
filter.
Style 1 - When the filter indicator reads 10%, order a new filter.
When the indicator reads 0%, it is recommended that you
replace the filter.
Style 2 - When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 - When the water filter status display changes from
“GOOD” to “ORDER,” order a new filter. When the filter indicator
reads “REPLACE,” it is recommended that you replace the filter.
Use replacement cartridge T1RFKB1, part #9030.
2008 suggested retail price of $59.99 U.S.A./$71.99 Canada.
Prices are subject to change without notice.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the “Warranty” section for the Manufacturer’s name,
address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33° - 100°F (0.6° - 37.8°C)
Service Flow Rate 0.5 gpm (1.9 L/min) @ 60 psi
‘Class I particle size: >0.5 to <1 um
"Test requirement is at least 100,000 partioles/mL of AC Fine Test Dust,
ttpibers greater than 10 um in length
♦Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
25