2Ć3 Site Planning and RequirementsC4699Ć90000
Choosing a Suitable Plotter Environment
(Instructions ' User's Guide, chapter 1, w Position the plotter.)
Environmental Specifications
Hardware: Environmental Class B2
Operating environment:
Plotter
With cartridges and media:
Temperature Relative Humidity
0 to 55_C (32 to 131_F) 5-25%
15 to 35_C (59 to 95_F) 20-80%
Storage environment:
Plotter/media
Cartridges
Temperature Relative Humidity
–40 to +70_C
(–40 to +158_F) 5-95%
–40 to +40_C
(–40 to +104_F)
Acoustics:*
Operating D/A1-size plotters
E/A0-size plotters
Idle
Sound Pressure Sound Power
43 dB (Acoustic) 6.0 bels (A)
45 dB (A)
< 20 dB (A) < 3.6 bels (A)
These specifications are typical sound pressures at a oneĆmeter bystander position. Idle specification
assumes fan is off.
Plotter Dimensions and Weight
Plotter Model: D/A1-size plotters E/A0-size plotters
Length
Depth
Height (window closed)
Weight
1028 mm (40.5 in) 1327 mm (52.2 in)
237 mm (9.3 in) 237 mm (9.3 in)
327 mm (12.9 in) 327 mm (12.9 in)
26 kg (57.2 lb) 31 kg (68.2 lb)