Electrical supply
WARNING
ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY
WITH THE NATIONAL ELECTRICAL CODE ! PROVINCIAL AND
MUNICIPAL CODES AND/OR OTHER LOCAL CODES,
DISCONNECT POWER SUPPLY,
The electrical supply must be a 120 Volt, 12 Amp, properly grounded,
positioned as shown in Fig. 7, and should be installed by a qualified
electrician. No other appliances or outlets should be on this circuit.
I
i
I
30" (760 mm
I
I
i!
alternate
location
Fig. 7
Cut a 1 inch hole in the cabinet for the electrical wiring to pass through.
If this hole is cut in a wood cabinet, the hole should be sanded until
smooth. If the hole is cut in a metal cabinet, the hole must be covered
by a grommet.
Run flexible cable from fuse disconnected circuit breaker or junction
box through hole in cabinet. Cable should extend 30" from back wall.
10