22
System components
Rest condition:
The seismic mass is situated exactly in the middle between the counter-electrodes. The two
capacitors C1 and C2 have the same capacitance.
292_026
Metal-plated electrodes
Capac-
itor C1
Capac-
itor C2
Silicon spring
*
Seismic mass
*
292_027
Acceleration
Capac-
itor C1
Capac-
itor C2
Seismic mass
Accelerated condition:
Mass inertia causes the seismic mass to be
deflected from its central position. The dis-
tance between the electrodes changes. As the
distance is reduced, the capacitance
increases.
In the example below, the capacitance of
capacitor C2 is greater than in rest condition,
whereas that of capacitor C1 decreases.
The supply voltage is provided by the pneu-
matic spring system’s control unit. The cur-
rent voltage values of body acceleration can
be read out by means of measured data
blocks.