Command Feedback Description
IPCFG IP Addr : x.x.x.x
Netmask : x.x.x.x
Gateway : x.x.x.x
IP Port : x
Displays IP address configure
IPQuit IPQuit Telnet Logout
IPAddUser [X] [Y] IPAddUser [X] [Y] IPAddUser [name] [password]. Add user of telnet.
If only command write “IPAddUser”, it will display all user list.
=> IPAddUser
IPDelUser [Y] IPDelUser [Y] IPDelUser [name]. Del user of telnet
IPDHCP [Y] IPDHCP [Y] IPDHCP [on/off/sta]. Set DHCP mode status and auto reset telnet.
Ex: Set DHCP mode is on => IPDHCP on
IPStatic [X] [Y] [Z] IPStatic [X] [Y] [Z] IPStatic [Address] [Netmask] [Gateway]. Set static IP address and
auto reset telnet.
Ex: Set static IP address is 192.168.1.1 255.255.255.0
192.168.1.254
=> IPStatic 192.168.1.1 255.255.255.0 192.168.1.254
IPPort [Y] IPPort [Y] IPPort [port]. Set telnet port and auto reset telnet
Ex: Set telnet port 80 => IPPort 80
IPLogin [Y] IPLogin [Y] IPLogin [on/off/sta]. Set telnet login status.
Ex: Set telnet login is on => IPLogin on
Broadcast [Y] Broadcast [Y] Broadcast [on/off/sta]. Broadcast switch.
Ex: Set broadcast mode is on => Broadcast on
IPTimeout [Y] IPTimeout [Y] IPTimeout [Sec]. Set telnet idle timeout time. Default is 2 minute.
Ex: Set telnet idle timeout 10 minutes => IPTimeout 600
Each command is terminated with a carriage return.
Feedback is terminated with a carriage return and line feed.
Note: If the command fails or is incorrect the feedback should be “Command FAILED”
IP Commands
Baud Rate
Zone RS-232 port conifiguration must match the connected device on all parameters including baud
rate, data-length, parity, and stop-bit. These parameters can easily be set using the WebGUI or
following commands through RS-232 or TCP/IP.
The baud rate for the switcher is for switcher control and the transmitter/receiver baud
rate is for control of the RS-232 device in zone. All commands from your control processor are
at the settings for the switcher. The switcher will modify the baud rate and other settings to these
set parameters by zone.
Note: Baud rate options 2400, 4800, 9600, 19200, 38400, 57600, or 115200
Note: Default for the switcher is: Baud rate-115200bps, Data length-8bit, Parity-None, Stop Bit-1
Command for Switcher Parameters
CSpara[baudrate,data-length,parity,stop-bit] (data, parity, and stop bit for switcher must be 8,0,1)
For example if you wish to change the baud rate of the switcher to 38400 the command would
look like this:
CSpara[38400,8,0,1]