Error Codes
53
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Edr Drain Alarm Error Machine not drained within 15 minutes (or other programmed
length of time) in any drain step. End cycle. Power down
machine to clear.
EHt Heat Alarm Error Programmed heat alarm time of 120 minutes or other
programmed length of time is exceeded. Turns off heater
output for remainder of cycle.
EoP Open Temperature Sensor Error Control senses temperature less than 0°F (-18°C) in machine
equipped with temperature sensor. Heater and thermistor
related operations are disabled.
ESH Shorted Temperature Sensor Error Control senses temperature greater than 220°F (104°C) in
machine equipped with temperature sensor. Heater and
thermistor related operations are disabled for remainder of
cycle.
Ero Rotation Sensor Error Invalid signal received from Rotation Sensor. Control will
activate coast times to complete cycle.
EFS Frame Balance Switch Error Control detects Frame Balance Switch open. End cycle.
Edb Drive Balance Switch Error Control detects VFD Balance Switch input closed at start of
drain step. End cycle. Power down machine to clear.
ELd Water Leak Detection Error Control senses a drop in water level during diagnostic testing,
power down machine to clear. When error occurs during a
cycle, “ELd” is displayed for one minute after opening the
door at the end of the cycle. When the error occurs during the
test, “ELd” is displayed immediately after the test until the
machine is powered down to clear the error.
ESd Slow Drain Error Control shows error after door is open (when cycle is
completed) for one minute, the error information will be
logged in audit data.
ELF* Water Leak Detection Error (Fill Valve) Control senses an increase in water level during diagnostic
testing, power down machine to clear. When error occurs
during a cycle, “ELF” is displayed for one minute after
opening the door at the end of the cycle. When error occurs
during a test, “ELF” is displayed immediately after the test
until the machine is powered down to clear the error.
*Design 4 models only.
Display Description Cause/Corrective Action
Table 17 (continued)