Dil ID: 10
Dil Adı: spain
Dil Kodu: es2tayfun Productos de la Marca Alliance Laundry Systems
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



7
3
Water drain
The machine is equipped with a drain valve with 6/4" outer diameter (50 mm). This
drain valve should be connected to the drain by means of the drain elbow which
is delivered with the machine.
p
p
p
The diameter of the main drain should be adapted to the water flow and the
number of machines. It should be sufficient to handle at least 80L/min. per
machine.
It is necessary to connect the main drain at least on one side to an open air-
brake to allow ventilation.
When the main drain has not been sufficiently deodorized, every machine
should be installed seperately with a deodorizer.
In case of machines with electrical heating two seperate connections
should always be used. One for the motor circuit, one for the heating.
After connection, check the spin direction. The cylinder must spin in the
direction of the arrow, showed on the sticker on the door window
(clockwise).
A wrong spin direction can damage the motor, and can also cause water
to spurt from the soap dispenser.
In case of wrong spin direction: switch the terminal clamps of the motor
circuit R and S of the connecting cable.
p
p
Main power connection
p
Machine with steam heating or boiler fed machine
without additional electrical heating
Value of mains fuses:
Motor circuit: 220V 3AC 380V 3AC + N
16A 16A
Motor
Motor
Heating
Machine with electrical
heating
Value of the mains fuses:
Motor circuit:220V 3AC380V 3AC + N
16A 16A
Heating: 220V 3AC 380V 3AC + N
12kw ---- 25A
15 kw 50A 25 A
18 kw 50 A 32 A
21 kw ---- 40 A
24 kw ---- 40 A