4.
Check the lid lock motor winding and
switches by removing
PI2 from the ma-
chinelmotor control and checking the
resistance values shown in the Lid Lock
Resistance table below:
If resistance values are good, go to
step 5.
If switch measurements do not match
the values shown in the table for un-
locked (or locked) conditions, a prob-
lem exists in the door lid lock. Replace
the door lid lock.
5.
If the Manual: Door Switch or Manual:
Door Lid Lock in step 1 failed, then the
machinelmotor control has failed:
Unplug washer or disconnect power.
Replace machinelmotor control as-
sem bly.
Perform the Manual: Door Switch and
Manual: Door Lid Lock in step 1 to ver-
ify
repair.
ACCESSING
&
REMOVING THE
ELECTRONIC ASSEMBLIES
There are two electronic assemblies; the ma-
chinelmotor control assembly and the user
interface assembly. See Figures 3 and
4
on
page 6-15.
Accessing the Electronic Assemblies
1.
Unplug washer or disconnect power.
2.
Remove three screws from the rear of ttie
console assembly. Pull console towards
front of washer to hinge open
andlor re-
move console.
Removing the MachinelMotor
Control Assembly
3.
Remove all the wire connections to
the machinelm~tor control.
6
-
4.
Remove the one screw holding the
machinelmotor control assembly to
the console tray.
5. There are two plastic legs on the rear
of the
machinelmotor control assem-
bly that fit into the console tray. Lift the
front of the control assembly to pivot it
out from the console tray.
Removing the User Interface Assembly
3. Remove the wire connection to the
user interface assembly.
4.
Remove the wash cycle selector knob
by firmly pulling on it.
5. The user interface assembly is held
to the console insert panel by three
screws and two locking tabs. After the
screws are removed,
lift each of the
locking tabs to remove the back cover
of the user interface assembly.
.
6. Remove the wash cycle selector
switch from the user interface assem-
bly opening by lifting the locking tab
on the wash cycle selector switch and
turning the selector switch in a coun-
terclockwise direction.
7.
Three locking tabs located at the bot-
tom of the console insert panel se-
cure the user interface assembly to
the console insert panel. Using a
flat-
blade screwdriver, gently apply pres-
sure to the locking tabs to release the
user interface assembly.
Reinstalling the Electronic Assemblies
1.
Refer to preceding removal sections and
replace in reverse order.
2.
Plug in washer or reconnect power.
NOTE:
When reconnecting wire connections,
route wires as shown in Figure 3, page 6-15.
Be sure to route wires beneath the retainer
clips on the
machinefmotor control, and en-
sure user interface assembly wire does not
get pinched between the console assembly
and the console tray when reassembling top.
NOTE:
Ensure the console gasket is in place
when reinstalling the console.