GB 9
Description of failure indications
Failure
indication
lights up
Description
Causes
Solutions
“Water tap closed”
Appliance has no or insufficient water supply. The “Start/Pause” light blinks.
Check whether:
• Water tap is fully open and water supply pressure is sufficient.
• Kinks are present in the water inlet hose.
• Mesh filter of water supply hose is blocked (see “Care And Maintenance”.
• The water hose is frozen up.
• The safety valve inspection window of your water supply hose is red (provided
your appliance has a water supply hose as shown on picture “D” - see previous
chapter “Care And Maintenance”); replace the hose by a new one available
through our After-Sales Service or your specialist dealer.
After problem has been removed, restart programme by pressing “Start/Pause”.
If the fault occurs again, contact our After-Sales Service (see next chapter).
“Clean pump”
Waste water is not pumped out. The appliance stops in the corresponding
programme step; unplug it and check whether:
• Kinks are present in the drain hose, or the hose is blocked for another reason.
• Filter or pump is blocked (see chapter “Draining Residual Water/Cleaning The
Filter”; make sure the water has cooled before draining the appliance).
• The drain hose is frozen up.
After problem has been removed, push the “Reset” button for at least 3 seconds;
afterwards restart the desired programme. If the fault occurs again, contact our
After-Sales-Service (see next chapter).