SERVICE
Whirlpool Europe ADP 242 S WH 25.01.2001 / Page 3
Customer Service 8542 242 10510 Doc. No: 4812 718 16125
Technical data
Heating
1 Element system
Voltage 220/230 V
Power consumption 1.87/2.04 kW
Resistance 24.5 Ω
Heating speed ~ 2.0 ˚C/min
Temperature on surface ~ 115 ˚C
Safety thermostat
self reset 85 ˚C
Potentiometer
Points of meassurement: 1(black) to 2 (middle)
Position 0 0.0 kΩ
Position 1 0.5 kΩ
Position 2 1.0 kΩ
Position 3 1.4 kΩ
Position 4 1.8 kΩ
Position 5 2.3 kΩ
Position 6 2.6 kΩ
Water valves
Single valve at inlet hose
Voltage 220/240 V
Frequency 50/60 Hz
Resistance 3.76 kΩ
Regenerating valve
Voltage 220/240 V
Frequency 50/60 Hz
Resistance 3.13 kΩ
Coil of dispenser
Voltage 220/240 V
Frequency 50/60 Hz
Resistance 1.5 kΩ
Reedcontact
flow meter
Accesory
If you need spare parts apart from the spare part
list have a look in the
Service Bulletin 4812 718 40084.
NTC
20 ˚C 58.1 kΩ
25 ˚C 47.1 kΩ
30 ˚C 38.2 kΩ
40 ˚C 25.4 kΩ
50 ˚C 17.2 kΩ
60 ˚C 11.8 kΩ
70 ˚C 8.3 kΩ
80 ˚C 6 kΩ
85 ˚C 4 kΩ
Regeneration
Volume 300 cm
3
Position 0
after wash cycles -
water hardness 0-5 ˚dh
0-0.9 mmol/l
0-9 ˚Fh
Position 1
after wash cycles 8
water hardness 6-10 ˚dh
1-1.8 mmol/l
10-18 ˚Fh
Position 2
after wash cycles 6
water hardness 11-15 ˚dh
1.9-2.7 mmol/l
19-27 ˚Fh
Position 3
after wash cycles 4
water hardness 16-21 ˚dh
2.8-3.7 mmol/l
28.37 ˚Fh
Position 4
after wash cycles 3
water hardness 22-28 ˚dh
3.8-5.0 mmol/l
38-50 ˚Fh
Position 5
after wash cycles 2
water hardness 29-35 ˚dh
5.1-6.3 mmol/l
51-63 ˚Fh
Position 6
after wash cycles 1
water hardness 36-60 ˚dh
6.4-10.7 mmol/l
64-107 ˚Fh
Salt consumption
for regeneration 77 g
Number of cycles
with 2 kg salt 26