Getting Started With Your System 21
I/O Module Specifications
For information about the I/O modules and pass-through modules supported
on your enclosure, see the Dell PowerEdge M1000e Systems Configuration
Guide at support.dell.com/manuals.
Relative humidity
Operating
20% to 80% (noncondensing) at a maximum wet bulb
temperature of 29 °C (84.2 °F)
Storage
5% to 95% (noncondensing) at a maximum wet bulb
temperature of 38 °C (100.4 °F)
Maximum vibration
Operating
0.26 Grms at 10 Hz–350 Hz for 15 min
Storage
1.54 Grms at 10 Hz–250 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis (one pulse
on each side of the system) of 41 G for up to 2 ms
Storage
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms
Altitude
Operating
–15.2 m to 3048 m (–50 ft to 10,000 ft)
Storage
–15.2 m to 10,600 m (–50 ft to 35,000 ft)
Airborne Contaminant Level
Class
G1 as defined by ISA-S71.04-1985
Environmental (continued)