
62
"
Power Defect
Power
Part
Problem in indoor
wiring
Problem in wiring
of washing
machin
Defect in electric
parts
Voltage check
• Breakdown of power lead-in switch
• Indoor wiring fuse short
• Aging of power outlet, defect in contact
• Extension cord short or too thin
• Power cord short (defect in contact)
• Lead wire short
• Controller terminal segments and connector loosened
• Defect in contact of electric wire connector (power switch, reactor)
• Breaking of insulated wire in lead wire terminal compression part
• Fuse short: In noise filter
• PCB transformer short
• Check input voltage