6-9. Motor-related Error
1) E5 (DC-Link High Voltage) Error
% In case DC-link voltage to IPM increases to 450V or higher
& Motor operation is stopped and 'E5' is shown in display window.
' Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
( Error display is cleared when turning off/ on power.
2) E6 (EMG) Error
% In case current detected with EMG port is of 20A or higher
& Motor operation is stopped and 'E6' is shown in display window.
' Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
( Error display is cleared when turning off/ on power.
3) E7 (Direction) Error
% In case signal of Hall IC is different from the predicted signal according to direction of rotation
& Motor operation is stopped and 'E7' is shown in display window.
' Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
( Error display is cleared when turning off/ on power.
4) E8 (Initial Operation Fail) Error
% In case input signal of Hall IC is abnormal due to problems in motor connection, etc.
& Motor operation is stopped and 'E8' is shown in display window.
' Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
( Error display is cleared when turning off/ on power.
6-10. Error in Temperature Sensor
1) H2 Error - Washing temperature sensor open/ short
% In case washing temperature sensor is defective or not connected
& Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
' Error display is cleared when turning off/ on power.
2) H4 Error - Washing temperature sensor overheating
% In case temperature detected by washing temperature sensor is 95) or higher
& Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
' Error display is cleared when turning off/ on power.