3-226
Chapter 3
Programming Using MMCs
804 SYSTEM I/O PARAMETER
Provides a means of setting parameters for the system I/O ports to work with one of the following:
- A personal computer
- SMDR recording
- UCD statistics report/periodic UCD information
- VM Trace for SVM-400
Programming can be accomplished easily, using the tables below to customise any I/O port.
PARAMETER OPTIONS
Dial 0 Service Type of Service
Dial 1 Baud Rate Speed
Dial 2 Char Length Character Length
Dial 3 Parity Parity Bit
Dial 4 Retry Count Number of Retries
Dial 5 Stop Bit Stop Bit
Dial 6 Wait Time Message Wait Time
Dial 7 DSR Check DSR Check on/off
SERVICE TYPE
Dial 0 PCMMC PCMMC
Dial 1 SMDR SMDR
Dial 2 UCD REPT
UCD Report on request by the
Supervisor, or daily
Dial 3 SMDR/UCD Both SMDR and UCD Report
will be generated
Dial 6 Not used
Dial 7 VM TRACE Trace for SVM-400
SPEED (BPS)
Dial 1 1200
Dial 2 2400
Dial 3 4800
Dial 4 9600
CHARACTER LENGTH
Dial 7 7 bits
Dial 8 8 bits
PARITY
Dial 0 None
Dial 1 Odd
Dial 2 Even
STOP BIT
Dial 1 1 bits
Dial 2 2 bits