Dil ID: 1
Dil Adı: english
Dil Kodu: en5 B2audio Brand's Products
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



22222
WIRING
PROGRAMMING
Circular connector M12x1, 5-pin
2 switching outputs + 1 analogue output
+ = 1 - = 3
SP1 = 4
SP2 = 2 = 5
0-10 V or 4-20 mA
(Min: LLR + 0.5% Max: ULR) Instrument Nominal Pressure
Menu (Programming and Factory Setting)
value
value
value
value
SP1 / FH1
RP2 / FL2
SP2 / FH2
RP1 / FL1
(Min: LLR Max: SP1 - 0.5%) Instrument Nominal Pressure - 10%
(Min: LLR + 0.5% Max: ULR) Instrument Nominal Pressure
(Min: LLR Max: SP2 - 0.5%) Instrument Nominal Pressure-
10%
Display-Mode
Programming-Mode
Long press on Menu Key
Factory Setting:
Legend:
LLR = lower limit of range
ULR = upper limit of range
YES/NO
value
value
value
value
PARA
PARA
unit
YES/NO
PARA
value
YES/NO
YES/NO
value
EF
RES
DS1
DR1
DS2
DR2
OU1
OU2
UNIT
0SET
PAS
RHL
DISU
DISR
DISM
(Return to Factory Settings)
(0 … 50 s) 0 s
(0 … 50 s) 0 s
(0 … 50 s) 0 s
(0 … 50 s) 0 s
(HNO, HNC, FNO, FNC) HNO
(HNO, HNC, FNO, FNC) HNO
(BAR, MPA, KPA, PSI, KG/cm²) Order dependent
(Zero Point Offset adjustment max. 3 %)
(ACT, HIGH, LOW, OFF,
SP1/FH1, RP1/FL1, SP2/FH2, RP2/FL2) ACT
(1/2/5/10 Updates/Second)
5 / s
(Display rotate 180°)
(Reset HIGH, LOW)
(Password) without
END
TAG
value
(Measuring Point number) without
Display-Mode
END
P-DPT:TEMPLATE 10/18/10 1:58 PM Page 2