Dil ID: 1
Dil Adı: english
Dil Kodu: en3 Audiobro Brand's Products
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



22222
AFR value is constantly 22.05 on “both cylinders”.
O2 sensors NOT plugged in.
O2 module not connected to DATA PLUG properly.
O2 module DATA PLUG not receiving 12V power.
Accessory fuse blown or corroded.
O2 module Faulty
AFR values (any value) always EXACTLY the same on “both cylinders.
O2 sensors NOT plugged in.
O2 module not connected to DATA PLUG properly.
O2 module DATA PLUG not receiving 12V power.
Accessory fuse blown or corroded.
O2 module Faulty
AFR value varies less than 0.5 (Example: 14.20 14.70) when throttle is twisted and released.
O2 sensor faulty
O2 sensor wiring damaged
Factory OEM sensors are PLUGGED IN
AFR value periodically indicates 19.36 or 22.05 on one cylinder.
O2 sensor plugs NOT securely SNAPPED together
O2 sensor harness plug wires pulled from plug. (Firmly pull on EACH wire at the connector)
O2 sensor faulty
O2 sensor connection broken
O2 sensor wire damaged (Melted by exhaust, rubbed through by drive belt, abrasion damage)
AFR value for ONE cylinder reads LEAN (AFR = 16.00 or greater always but engine idles good)
Exhaust gasket leak.
Weld at O2 sensor leaking (Use Soapy Water test to determine)
Crack in affected cylinder’s exhaust pipe