45641001TH Rev.1
11-91 /
Oki Data CONFIDENTIAL
05/
08
Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System Network E-mail 9959 Bcc address
display ON/OFF
setting (Job
Notification)
1 0-1 SYS Sets whether the Bcc address is displayed or not on all
theJobNoticationsexceptfortheadministratorwhen“1:
To/Bcc”isselectedinthecode08-9957.
0: OFF (Bcc address not displayed)
1: ON (Bcc address displayed)
1
08 Setting
Mode
System
Maintenance
9960 Display of
equipment
information
(SRAM)
Refer to
contents
0-2 SYS DisplaystheequipmentinformationinSRAM.
0: Not set
1: H-290/291
2: H-290/291 for ODA
<Default value>
ODA: 2
Others: 1
2
08 Setting
Mode
System User
interface
Default mode
setting
Default setting
(PPC)
9970 Original mode
(Black)
0 0-4 SYS 0: Text/Photo
1: Text
2: Photo
3: Gray Scale
4: User custom mode
1
08 Setting
mode
System General Default setting Imagequality
density
9971 PPC (black) 0 0-1 SYS 0: Auto
1: Manual
1
08 Setting
mode
System General Default setting Blank page
judgment:Default
setting
9972 PPC 0 -3-3 SYS Thelargerthevalue,themorethepaperisjudgedasa
blankpage.Thesmallerthevalue,thelessthepaperis
judgedasablankpage.
1
08 Setting
mode
System User
interface
Default setting Blank page
judgment:Default
setting
9973 SCN 0 -3-3 SYS Thelargerthevalue,themorethepaperisjudgedasa
blankpage.Thesmallerthevalue,thelessthepaperis
judgedasablankpage.
1
08 Setting
mode
System User
interface
Default setting ACSjudgment
adjustment:
Default setting
9975 SCN 2 -3-3 SYS Thelargerthevalue,themoretheoriginalisjudgedas
colordata.Thesmallerthevalue,thelesstheoriginalis
judgedasblackdata.
1
08 Setting
mode
System Network Email 9980 Receiver’s address
fixing function at
authentication
0 0-4 SYS Sets address of TO/CC/BCC when the user authentication
and E-mail authentication are enabled.
Whenthevalueofthiscodeissetto“1”,theaddress
specified as From Address is input to TO destination field.
TO/CC/BCC field cannot be edited.
Whenthevalueofthiscodeissetto“2to4”,theaddress
specified as From Address is input to each field. TO/CC/
BCC field can be edited by pressing the TO/CC/BCC
button.
0: Disabled
1: Fixed to TO field.
2: Added to TO field.
3: Added to CC field.
4: Added to BCC field.
1