1212121212
Problem Possible cause Solution
The thickness of the frost
is greater than 4-5 mm.
Defrost the appliance.
The door has been
opened often.
Open the door only if neces‐
sary.
There is no cold air circu‐
lation in the appliance.
Make sure that there is cold
air circulation in the appli‐
ance.
If the advice does not lead to
the desired result, contact
the nearest Authorised
Service Centre.
7.2 Replacing the lamp
Disconnect the plug from the mains
socket.
1. Remove the screw from the lamp
cover.
2. Remove the lamp cover (refer to the
illustration).
3. Replace the used lamp with a new
lamp of the same power and
specifically designed for household
appliances (the maximum power is
shown on the lamp cover).
4. Install the lamp cover.
5. Tighten the screw to the lamp cover.
6. Connect the plug to the mains
socket.
7. Open the door.
Make sure that the light comes on.
7.3 Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer
to assembly instructions.
3. If necessary, replace the defective
door gaskets. Contact the Authorised
Service Centre.
8. INSTALLATION
8.1 Location
Refer to the assembly
instructions for the
installation.
To ensure best performance, install the
appliance well away from sources of heat
such as radiators, boilers, direct sunlight
etc. Make sure that air can circulate
freely around the back of the cabinet.
8.2 Positioning
Install the appliance in a dry, well
ventilated indoors where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance.
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
www.electrolux.com12