Parameter
Value Note Default
55 y
Time before number dialing
1
y – is time [sec] after picks up the line and dialing the number [range 1-5
sec]. This time is different for each PBX type but usually all PBXs works
with time up 2 seconds.
List of corresponding parameters: 8# 85
Parameter
Value Note Default
56 h
Number of days after which is perform service
call
3
h [1 ÷ 9 days] after programmed time in parameter 21 eventually parameter
1 the LLW call to service department to notify its full operation
( functionality). The time from last call is display in Lift set programm.
List of corresponding parameters: 31 32 36 45
Parameter
Value Note Default
57 t
The time of DTMF dial (tone) duration
5 (100ms)
58 m
The time of space between DTMF tones
5 (100ms)
59 f
The time of Flash
1 (100ms)
50 p
The time of pause /internumeral space
8 (800ms)
t the time of tone duration is calculate:
(insert number + 5) x 10 = tone duration time [ms]
[range 1-0 , it is 60-150ms]
m the time of space between tones is calculate:
(insert number + 5) x 10 = space duration time [ms]
[range 1-0, it is 60-150ms]
f the time of Flash is calculate:
insert number x 100 = Flash duration time [ms]
[range 1-6, it is 100-600ms]
p the time of pause is calculate:
insert number x 100 = pause duration time [ms]
[range 5-0 , it is 500-1000ms]
time p is simultaneously time of internumeral space in pulse
dialing
List of corresponding parameters: 1 21 22 serial number sending