International Standards Laboratory Report Number: ISL-05HE084E
HC LAB:NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178
LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-2-
2. Summary
2.1 Operation Environment
Power supply : AC 230 V / 50 Hz
2.2 Test Standards
The immunity tests which this report describes were conducted by an independent
electromagnetic compatibility consultant, International Standards Laboratory in
accordance with the
EN55024: 1998/A1:2001/A2: 2003; EN61000-6-2:2001, AS/NZS CISPR 24: 1997:
Information technology equipment-Immunity characteristics-Limits and methods of
measurement.
Standard Description Results Criteria
EN61000-4-2: 1995/A1: 1998/A2: 2001
IEC61000-4-2: 1995
AS/NZS 61000.4.2: 2002
Electrostatic Discharge Pass A A
EN61000-4-2: 1995/A1: 1998/A2: 2001
IEC61000-4-2: 2001
AS/NZS 61000.4.2: 2002
Radio-Frequency, Electromagnetic
Field
Pass A A
EN61000-4-3: 2000/A1: 2002
IEC61000-4-3: 2002
AS/NZS 61000.4.3: 1999
Electrical Fast Transient/Burst Pass A A
EN61000-4-4: 1995/A1: 2001/A2: 2001
IEC61000-4-4: 1995+A1:2000+A2:2001
AS/NZS 61000.4.4: 1999
Surge Pass A A
EN61000-4-5: 1995/A1: 2001
IEC61000-4-5: 2001
AS/NZS 61000.4.5: 1999
Conductive Disturbance Pass A A
EN61000-4-8: 1993/A1: 2001
IEC61000-4-8: 2001
AS/NZS 61000.4.8: 2002
Power Frequency Magnetic Field Pass A A
EN61000-4-11: 1994/A1: 2001
IEC61000-4-11: 2001
AS/NZS 61000.4.11: 1999
Voltage Dips / Short Interruption and
Voltage Variation
>95% in 10ms Pass A A
30% in 500ms Pass A A
ONLY ON IEC61000-4-11: 2001 60% in 100ms Pass A A
>95% in 5000ms Pass B B
Standard Description Results
EN61000-3-2: 2000
AS/NZS 61000.3.2: 2003
Limits for harmonics current emissions Pass
EN61000-3-3: 1995
A1: 2001/ AS/NZS 61000.3.3: 1998
Limits for voltage fluctuations and flicker in
low-voltage supply systems.
Pass