Dil ID: 1
Dil Adı: english
Dil Kodu: en6tayfun Acura Embedded Brand's Products
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



8888888888
Appendix D: Power Consumption
Appendix D: Power Consumption
Power Consumption Management
Purpose
The purpose of the power consumption test is to verify the power dissipation
of the system and the load of the power supply.
Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver:2.0
Device Under Test
DUT: sys#1/
Test Procedure
1. Power up DUT and then boot Windows 7.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.
AcuPanel 15
Full-Loading Mode
Total
Standby Mode
Total
+12V
3.2A
38.4W
0.75A
9W
+24V
1.65A
39.6W
0.41A
9.84W
+30V
1.26A
37.8W
0.36A
10.8W
83