O-30
Cameo 2/3 Series User Guide
8
7
6
4
2
1
5
3
Communications Port
Pin Pin Signal Signal
Number Name Type Description
1 RXD input Receive Data
2 TXD output Transmit Data
3 CTS input Clear To Send from host
4 RTS output Request To Send
set high when printer is
ready to accept command/
data
5 GND Ground
6 NC No Connect
7 DSR input Data Set Ready: Low to high
transition turns printer on,
High to low transition turns
printer off (if enabled)
8 DTR output Data Terminal Ready
high when printer is on (set at
battery voltage for “S” option)
Power
Cameos utilize removable NiMH battery packs. If not connected to a
terminal with DTR present, the Cameo will automatically power off to
conserve battery life. The time-out value can be programmed from
the host terminal; the factory default time-out is two minutes.
Additional power features include:
Low battery indicated by flashing LED and reported to terminal on demand
Power On/Off controlled from terminal or keypad
Communications Port (8 pin Circular DIN)