3.32 F 56 No spin action
Symptom
Final spin speed < 400 min
-1
, when the target spin speed is at least 450 min
-1
.
Fault detection: Tachogenerator
Cause
Final spin speed < 400 min
-1
, when the target spin speed is at least 450 min
-1
.
Remedy
A Check the dosage, refer to F 16 Oversudsing, 070 3.17.
A Check the drive, refer to Drum drive defective, 060 3.1.
3.33 F 63 Water path control fault
Symptom
In the operating mode the display indicates: Technical fault.
The LED “water intake” flashes rapidly.
The program is stopped, the water intake valve is closed, and the drain pump is
switched on for 120 seconds.
Cause
Defective water path system.
The ELP does not detect a valid position, approx. 80 seconds after the water path
system is switched on.
x
Note
The water intake can only proceed if a valid water path position is registered.
Check the water path system
A Check the water path system for short circuit, open circuit and isolation.
Descriptive Technical Documentation
DTD no. 11-4800 070-31
22.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.