2 Function
2.1 Pull door lock (A2)
2.1.1 Electromagnetic door lock
When locking the door, the locking latch dips into the lock and is pulled into the
lock by the locking mechanism.
The power electronic (ELP) registers the locked state via a switch in the door lock
(A2).
During operation, with the door closed, the door lock is electromagnetically
bolted, refer to 020 2.1.2 Safety requirements.
As long as the door is not electromagnetically bolted, the door can be opened by
simply pulling it.
Activating the emergency release cancels the electromagnetic lock, and the door
can be opened.
x
Danger!
Opening the door by means of the emergency release may present danger of
injury by a rotating drum, danger of scalding suds and flooding.
Note
Closing the door when the door lock is already locked causes damage to the
door lock.
If the door lock is locked, with the door open, it has to be released manually,
refer to Door lock (A2) – Open manually, 020 4.1.
2.1.2 Safety requirements
After pressing the “Start” pad, the electromechanical door lock is only activated
when the following safety requirements are met:
– Drum speed < 7 min
-1
, registered by RPM sensor (Tachogenerator),
– Water level < 80 mmWS, registered by analog pressure sensor (ADS),
– Suds temperature < 131°F (55°C), registered by suds temperature sensor
(NTC resistor R30).
Descriptive Technical Documentation
DTD no. 11-4800 020-3
22.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.