Connections with third-party devices or panels are enabled
in the Eclipse using a variety of interface modules.
INTERFACE MODULES
10 Clear-Com Eclipse
FOR-22 (Dual 4-wire Transformer Balance and Radio
Relay Control Module)connects two external four-wire
circuits to the matrix. The module provides proper
impedance matching, transformer isolation and level
adjustments between systems. It also supports external
relay activation and call-sense circuitry.
CCI-22 (Dual Partyline Ring Interface Module)
connects two 2-wire full-duplex partyline circuits with
the matrix. The interface supports Clear-Com signaling
to and from the matrix system, deriving its power from
the external partyline circuit. Levels and cable nulling
are completely adjustable. The CCI-22 functions with
Clear-Com and other two-wire intercom systems.