69-0756B—2
Replacing electronic
air cleaner components
STEP 1 Inspect the cell(s) for broken ionizer wires and
bent collector plates. Repair as necessary or
take to a Honeywell Authorized Air Cleaner
Repair Station.
STEP 2 Slide the prefilter(s) into the upstream prefilter
guides.
STEP 3 Slide the air cleaner cell(s) in so the air flow
arrow points downstream and the handle(s)
face outward.
STEP 4 Firmly close the access door.
STEP 5 Turn on the air cleaner. If the cell(s) and
prefilter(s) are wet, the neon light may not come
on and you may hear arcing. If the arcing is
annoying, simply turn the air cleaner off for 2-3
hours or until the cell(s) are dry.
If your air cleaner has an Air Cleaner Monitor,
the FAULT indicator may activate if you install
wet cell(s) and prefilter(s). Again, if the neon
light or the FAULT indicator annoys you, simply
turn off the air cleaner for 2-3 hours or until the
cell(s) and prefilter(s) are dry.
M3582
12