C – Configuring CHAP
Configuring CHAP Using CLI
FI0054601-00 C C-3
A
CLINormal SessionBi-directional CHAP
To configure a bi-directional CHAP used during a normal session:
1. On the router
a. Enable CHAP on the presented target to which the initiator will login.
b. Create a secret (for example, secret_target).
c. Use Set CHAP.
2. Use Initiator add to add the initiator that is about to do a normal login:
a. Enable the CHAP for this initiator.
b. Create a secret (for example, secret_initiator).
c. Use Set Chap to update the CHAP settings of the initiator.
3. Go to the MS Initiator and perform the following steps:
a. Click General.
b. Click Secret (in the middle of the screen).
c. If this is the first time you are setting secrets, reset all the secrets.
d. Type the secret (secret_target) that you created in Step 1.
4. Click Targets.
5. Select the target you want to login to.
6. Click Advanced.
7. Select Chap Login Information.
8. Type the secret (secret_initiator) that you created in Step 2 into Target
Secret.
9. Select Mutual Authentication.
10. Click OK.
11. Click OK. The initiator completes the normal login.