HEATERS
- Blower Assembly
24-15
--I
Front wirina harness
d
!
2OW537
2OW768
2OW779
5. REMOVAL OF BLOWER ASSEMBLY
(1) Disconnect the connector of the front wiring harness
(connected to the resistor).
(2) Remove the ground installation bolt. (Tightened togeth-
er with the blower assembly.)
(3) Remove the blower assembly installation bolt.
INSPECT00
N24KCAD
RESISTOR
Connect an ohmmeter to each terminal of the resistor and
measure the resistance.
Terminal
connections
1
-2(M1)
1 -3(M2)
I-4(Low)
1 - 5 (High)
BLOWER MOTOR
Resistance
Approx. 1.22R
Approx. 0.41 R
Approx. 2.25112
Approx. OlR
(1) Connect the blower motor terminals directly to the battery
and check that the blower motor operates smoothly.
(2) Next, reverse the polarity and check that the blower motor
operates smoothly in the reverse direction.
SERVICE POINTS OF INSTALLATION
N24KDAC
3. INSTALLATION OF AIR SELECTION CONTROL WIRE
Connect the air selection control wire to the air selection
damper lever by following the steps below.
(1) Move the air selection control lever to the& position.
(2) With the air selection damper lever pressed inward in
the direction indicated by the arrow, connect the inner
cable of the air selection control wire to the end of the
air selection damper lever, and then secure the outer
cable by using a clip.