Appendixes
MTASR3
67
Dial string modifiers:
L Redial last number. (Must be placed immediately after ATD.)
P Pulse-dial following numbers in command .
T Tone-dial following numbers in command (default).
V Switch to speakerphone mode and dial the following number. Use ATH command to hang up.
W Wait for a new dial tone before continuing to dial. (X2, X4, X5, X6, or X7 must be selected.)
S Dial a phone number previously stored using the &Zn=x command (see &Zn=x command for
further information). The range of n is 0-3.
, Pause during dialing for time set in register S8.
; Return to command mode after dialing. (Place at end of dial string.)
! Hook flash. Causes the modem to go on-hook for one-half second, then off-hook again.
@ Wait for quiet answer. Causes modem to wait for a ringback, then 5 seconds of silence, before
processing next part of command. If silence is not detected, the modem returns a NO ANSWER
code.
$ AT&T's "call card" tones detection.
^ Disable data calling tone transmission.
Command: DS=
n
Dial Stored Telephone Number
Values:
n
= 0–3
Default: none
Description: Dial a number previously stored in directory number
n
by the
&Zn=x
command .
Example: ATDS=3
Command: E
n
Echo Command Mode Characters
Values:
n
= 0 or 1
Default: 1
Description: E0 Do not echo keyboard input to the terminal.
E1 Do echo keyboard input to the terminal.
Command: F
n
Echo Online Data Characters
Values:
n =
1
Default: 1
Description: F0 Enable online data character echo. (Not supported.)
F1 Disable online data character echo (included for backward compatibility with some software).
Command: H
n
Hook Control
Values:
n
= 0 or 1
Default: 0
Description: H0 Go on-hook to hang up.
H1 Go off-hook to make the phone line busy.
Command: I
n
Information Request
Values:
n
= 0–4, 9, 11
Default: None
Description: I0 Display default speed and controller firmware version.
I1 Calculate and display ROM checksum (e.g., “12AB”).
I2 Check ROM and verify the checksum, displaying
OK
or
ERROR
.
I3 Display default speed and controller firmware version.
I4 Display firmware version for data pump (e.g., “94”).
I9 Display country code (e.g., “NA Ver. 1”).
I11 Display Diagnostic Information for the last Modem Connection (i.e., DSP and Firmware version,
Link Type, Line Speed, Serial Speed, Type of Error Correction/Data Compression, Number of past
Retrains,etc.)
Command: L
n
Monitor Speaker Volume
Values:
n
= 0, 1, 2, or 3
Default: 2
Description: L0 Select low volume.
L1 Select low volume.
L2 Select medium volume.