Dil ID: 9
Dil Adı: germany
Dil Kodu: de7tayfun Produkte der Marke Printronix
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



Specification Check-Bar Code — X'04'
51
Explanation: The unit/module width specified in the Write Bar Code Data
Descriptor field is not supported.
Alternate Exception Action:
Use closest smaller width supported or the device default for those devices
with only one fixed default value.
Explanation:
The element height specified in the Write Bar Code Data Descriptor field is
not supported.
Alternate Exception Action: Use closest height supported.
Explanation:
The height multiplier specified in the Write Bar Code Data Descriptor field is
not supported.
Alternate Exception Action: Use closest multiplier supported.
Explanation:
The wide/narrow ratio specified in the Write Bar Code Data
Descriptor field is not supported.
Alternate Exception Action:
Use the printer default wide element width. The default wide element width
and the specified or default unit/module width should be such that a wide/nar-
row ratio of 2.50 or 3.00 results.
Explanation:
The symbol reference point given in the Write Bar Code command is not a
valid or supported value.
Alternate Exception Action: None.
X'040600' Unit/Module Width Specified Is Not Supported
X'040700' Element Height Specified Is Not Supported
X'040800' Height Multiplier Specified Is Not Supported
X'040900' Wide/Narrow Ratio Is Not Supported
X'040A00' Invalid Symbol Reference Point